NPS 34 Schedule 20 Pipe

34.000 in (863.6 mm) outside diameter on a 0.500 in (12.7 mm) wall, giving a 33.000 in (838.2 mm) bore and 178.89 lb/ft (266.22 kg/m) empty. ASME B36.10M.

Nominal size
NPS 34 (DN 850)
Schedule
Schedule 20
Outside diameter
34.000 in (863.6 mm)
Wall thickness
0.500 in (12.7 mm)
Inside diameter
33.000 in (838.2 mm)
Weight, empty
178.89 lb/ft (266.22 kg/m)
Weight, water filled
549.69 lb/ft (818.02 kg/m)
Flow area
855.299 in² (551804 mm²)

In NPS 34 this wall thickness is also designated Extra Strong (XS). That is the same pipe under another name, not a different product — but the coincidence is specific to this size and does not hold across the range.

Every schedule in NPS 34

Dimensions are given in inches, with the millimetre equivalent beneath in grey.

ASME B36.10M schedules published in NPS 34, outside diameter 34.000 in (863.6 mm).
ScheduleWall thicknessInside diameterWeight, emptyWater (US gal/ft)
Sch 100.3127.92 mm33.376847.75 mm112.26167.05 kg/m45.449
Sch 20 this page0.50012.70 mm33.000838.20 mm178.89266.22 kg/m44.431
Sch 300.62515.88 mm32.750831.85 mm222.78331.54 kg/m43.760
Sch 400.68817.48 mm32.624828.65 mm244.78364.27 kg/m43.424
STD0.3759.52 mm33.250844.55 mm134.67200.41 kg/m45.107
XS0.50012.70 mm33.000838.20 mm178.89266.22 kg/m44.431

Weight is plain-end carbon steel, w = 10.6802 × t × (OD − t) lb/ft.

Common questions

What is the inside diameter of NPS 34 schedule 20 pipe?

33.000 in (838.2 mm). The outside diameter is fixed at 34.000 in (863.6 mm) by ASME B36.10M, and the 0.500 in (12.7 mm) wall takes 1.000 in off it — 0.500 in from each side — leaving that bore.

How much does NPS 34 schedule 20 pipe weigh?

178.89 lb/ft (266.22 kg/m) empty, as plain-end carbon steel. Full of water it comes to 549.69 lb/ft (818.02 kg/m), because the bore holds 44.431 US gallons per foot. One short ton of this pipe is about 11 ft.

Does NPS 34 schedule 20 pipe use special flanges or fittings?

No. Flanges and buttweld fittings are dimensioned from NPS, so NPS 34 hardware fits this pipe in any schedule. The one thing that does follow the schedule is the bore of a weld neck flange or a fitting end prep, which has to be 33.000 in (838.2 mm) to match.