NPS 10 Pipe Dimensions

Outside diameter 10.750 in (273.1 mm) — fixed across every schedule. 14 wall thicknesses from ASME B36.10, with bore, weight, flow and pressure capacity for each, and the flanges and fittings that go with the size.

Nominal size
NPS 10
Metric designator
DN 250
Outside diameter
10.750 in (273.1 mm)
Schedules listed
14
Standard weight wall
0.365 in (9.3 mm)
Extra strong wall
0.500 in (12.7 mm)

What NPS 10 is

NPS 10 pipe measures 10.750 in (273.1 mm) across the outside, which is 0.750 in more than the 10 in its name suggests. Below NPS 14 the designation is a label inherited from iron pipe sizing and matches neither the outside diameter nor the bore of any schedule exactly. The metric designator is DN 250, which is likewise a label and not a measurement in millimetres. Whatever the schedule, the outside diameter stays at 10.750 in (273.1 mm): a heavier wall grows inward and takes the difference out of the bore.

A common size for main process lines, cooling water and flare sub-headers.

Pipe wall thickness to scale, NPS 10Pipe cross-sections drawn to scale at the same outside diameter so the wall thicknesses can be compared. Sch 5: 0.134 in wall · 10.482 in bore; STD: 0.365 in wall · 10.020 in bore; Sch 160: 1.125 in wall · 8.500 in boreSch 50.134 in wall · 10.482 in boreSTD0.365 in wall · 10.020 in boreSch 1601.125 in wall · 8.500 in bore
NPS 10 pipe drawn to scale. Every section is 10.750 in (273.1 mm) across the outside. Only the wall changes, and the bore takes up the difference.

Every schedule in NPS 10

Dimensions are given in inches, with the millimetre equivalent beneath in grey.

ASME B36.10 wall thicknesses for NPS 10 (DN 250), outside diameter 10.750 in (273.1 mm).
ScheduleWall thicknessInside diameterWeight, emptyWeight, water filledFlow area (in²)Water (US gal/ft)
Sch 50.1343.40 mm10.482266.24 mm15.2122.63 kg/m52.6278.30 kg/m86.294.483
Sch 100.1654.19 mm10.420264.67 mm18.6727.78 kg/m55.6482.80 kg/m85.284.430
Sch 200.2506.35 mm10.250260.35 mm28.0641.76 kg/m63.8395.00 kg/m82.524.287
Sch 300.3077.80 mm10.136257.45 mm34.2751.00 kg/m69.25103.06 kg/m80.694.192
Sch 400.3659.27 mm10.020254.51 mm40.5260.30 kg/m74.71111.17 kg/m78.854.096
STD0.3659.27 mm10.020254.51 mm40.5260.30 kg/m74.71111.17 kg/m78.854.096
Sch 600.50012.70 mm9.750247.65 mm54.7981.53 kg/m87.15129.70 kg/m74.663.879
Sch 800.59415.09 mm9.562242.87 mm64.4995.97 kg/m95.62142.30 kg/m71.813.730
XS0.50012.70 mm9.750247.65 mm54.7981.53 kg/m87.15129.70 kg/m74.663.879
Sch 1000.71918.26 mm9.312236.52 mm77.10114.74 kg/m106.62158.67 kg/m68.103.538
Sch 1200.84421.44 mm9.062230.17 mm89.38133.01 kg/m117.34174.62 kg/m64.503.350
Sch 1401.00025.40 mm8.750222.25 mm104.23155.11 kg/m130.30193.90 kg/m60.133.124
Sch 1601.12528.57 mm8.500215.90 mm115.75172.26 kg/m140.35208.87 kg/m56.752.948
XXS1.00025.40 mm8.750222.25 mm104.23155.11 kg/m130.30193.90 kg/m60.133.124

Inside diameter is OD − 2t. Weight is calculated for carbon steel as w = 10.69 × t × (OD − t) lb/ft and is the plain-end weight, excluding coatings, linings and fittings. Water-filled weight adds fresh water at 8.3454 lb per US gallon.

Reading the table

B36.10 lists 14 designations in NPS 10, which between them give 11 different wall thicknesses. The lightest is Schedule 5 at 0.134 in (3.4 mm) and the heaviest is Schedule 160 at 1.125 in (28.6 mm). Going from one to the other takes the bore from 10.482 in (266.2 mm) down to 8.500 in (215.9 mm), which cuts the flow area by 34% and raises the weight from 15.21 to 115.75 lb/ft, a factor of 7.6.

Standard weight equals Schedule 40 in this size. Extra strong equals Schedule 60. Where two designations share a wall they are the same pipe under two names, and either may appear on a mill certificate. The match is specific to the size, so it is the wall thickness in inches that should go on a requisition, not the designation alone.

For handling and support loads, a 20 ft length of standard weight NPS 10 pipe weighs about 810 lb (368 kg) empty and 1494 lb (678 kg) full of water. The water-filled figure is the one that governs pipe support spacing and the load during a hydrostatic test, including on lines that will carry gas or vapour in service.

Flow and pressure capacity by schedule

Two questions decide a schedule: how much the bore will carry, and how much pressure the wall will hold. The flow columns give the water flow through each bore at three velocities that bracket ordinary liquid service, from a pump suction line at the low end to a pump discharge line at the high end. The pressure columns are the ASME B31.3 pressure design equation solved for pressure, first on the nominal wall and then on the wall after the 12.5% mill under-tolerance that seamless pipe is allowed.

Water flow and internal pressure capacity of NPS 10 pipe by schedule.
ScheduleFlow at 3 ft/s (US gpm)Flow at 6 ft/s (US gpm)Flow at 10 ft/s (US gpm)Pressure, nominal wallPressure, wall less 12.5%
Sch 5806.91,613.82,689.7504 psig440 psig
Sch 10797.41,594.82,657.9622 psig543 psig
Sch 20771.61,543.22,571.9948 psig827 psig
Sch 30754.51,509.02,515.01,169 psig1,020 psig
Sch 40737.31,474.72,457.81,396 psig1,217 psig
STD737.31,474.72,457.81,396 psig1,217 psig
Sch 60698.11,396.32,327.11,932 psig1,683 psig
Sch 80671.51,342.92,238.22,312 psig2,012 psig
XS698.11,396.32,327.11,932 psig1,683 psig
Sch 100636.81,273.62,122.72,827 psig2,456 psig
Sch 120603.11,206.22,010.33,351 psig2,908 psig
Sch 140562.31,124.51,874.24,020 psig3,483 psig
Sch 160530.61,061.21,768.74,569 psig3,952 psig
XXS562.31,124.51,874.24,020 psig3,483 psig

Flow is velocity × flow area. Pressure is P = 2·S·t / (D − 2·Y·t) with S = 20,000 psi, E = W = 1.0 and Y = 0.4: seamless carbon steel such as A106 Gr B at moderate temperature, with no corrosion allowance and no threading allowance. It is an illustration of the arithmetic, not a design rating.

The method behind both halves of that table is set out in the pipe sizing guide and the wall thickness guide, each with a worked example.

Flanges for NPS 10 pipe

ASME B16.5 sizes a flange from the NPS and the pressure class, never from the schedule, so every flange below fits every wall in the table above. In NPS 10 a Class 150 flange is 16.00 in (406.4 mm) across and 1.12 in (28.4 mm) thick, held by 12 bolts of 7/8 in. A Class 2500 flange for the same pipe is 26.50 in (673.1 mm) across and 6.50 in (165.1 mm) thick, on 12 bolts of 2 1/2 in. Because the bolt circle moves with the class, flanges of two different classes will not bolt together even though both fit the pipe.

ASME B16.5 flange dimensions in NPS 10, all published pressure classes.
ClassFlange ODThicknessBolt circleBoltingRaised face ODRating @ 100 °F
Class 15016.00406.40 mm1.1228.45 mm14.25361.95 mm12 × 7/8 in12.75323.85 mm285 psig
Class 30017.50444.50 mm1.8145.97 mm15.25387.35 mm16 × 1 in12.75323.85 mm740 psig
Class 40017.50444.50 mm2.1253.85 mm15.25387.35 mm16 × 1 1/8 in12.75323.85 mm985 psig
Class 60020.00508.00 mm2.5063.50 mm17.00431.80 mm16 × 1 1/4 in12.75323.85 mm1480 psig
Class 90021.50546.10 mm2.7569.85 mm18.50469.90 mm16 × 1 3/8 in12.75323.85 mm2220 psig
Class 150023.00584.20 mm4.25107.95 mm19.00482.60 mm12 × 1 7/8 in12.75323.85 mm3705 psig
Class 250026.50673.10 mm6.50165.10 mm21.25539.75 mm12 × 2 1/2 in12.75323.85 mm6170 psig

Ratings are for A105 carbon steel at 100 °F and fall with temperature. Thickness excludes the raised face. All six flange types share these dimensions.

The one flange dimension that does follow the schedule is the bore of a weld neck flange, which is machined to the inside diameter of the pipe it is welded to. A weld neck flange for standard weight NPS 10 pipe is bored 10.020 in (254.5 mm); ordered for Schedule 160 it is bored 8.500 in (215.9 mm). The schedule therefore belongs on every weld neck flange requisition.

ASME B16.5 length through hub, NPS 10.
ClassWeld neckSlip-on / threadedLap jointRaised face height
Class 1503.94100.08 mm1.8847.75 mm1.9449.28 mm0.06 in (1.5 mm)
Class 3004.56115.82 mm2.5665.02 mm3.7595.25 mm0.06 in (1.5 mm)

Length through hub is how far the flange stands off the joint, which is what a spool drawing needs. It is measured from the flange face, without the raised face, and is tabulated here for Classes 150 and 300.

Buttweld fittings for NPS 10 pipe

ASME B16.9 sets the dimensions of a buttweld fitting from the NPS alone, so the figures below hold for every schedule in the size. A long radius 90° elbow in NPS 10 measures 15.00 in (381.0 mm) from its centre to each end, which is the figure a piping layout adds for every change of direction. The fitting is still ordered to a schedule, because its wall has to match the pipe at the weld.

ASME B16.9 buttweld fitting dimensions in NPS 10.
FittingDimensionNPS 10
90° Long Radius ElbowCentre-to-end A15.00381.00 mm
90° Short Radius ElbowCentre-to-end A10.00254.00 mm
45° Long Radius ElbowCentre-to-end B6.25158.75 mm
180° Long Radius Return BendCentre-to-centre O30.00762.00 mm
Straight TeeCentre-to-end C and M8.50215.90 mm
Reducing TeeRun centre-to-end C8.50215.90 mm
Straight CrossCentre-to-end C8.50215.90 mm
Concentric ReducerEnd-to-end H7.00177.80 mm
Eccentric ReducerEnd-to-end H7.00177.80 mm
CapLength E5.00127.00 mm

The cap is the exception to the rule above: its length is for walls up to a limiting thickness, and a heavier wall takes a longer cap. See the cap page.

Guides and comparisons for this page

NPS 10 in each schedule chart

Common questions

What is the outside diameter of NPS 10 pipe?

NPS 10 pipe has an outside diameter of 10.750 in (273.1 mm). That outside diameter is fixed: it is identical in every schedule, and only the wall thickness — and therefore the bore — changes from one schedule to the next.

What is the inside diameter of NPS 10 schedule 40 pipe?

10.020 in (254.5 mm). The 0.365 in (9.3 mm) wall comes off the 10.750 in (273.1 mm) outside diameter twice, once on each side, which leaves that bore and a flow area of 78.85 in².

How much does NPS 10 schedule 40 pipe weigh?

40.52 lb/ft (60.30 kg/m) as plain-end carbon steel, on a wall thickness of 0.365 in (9.3 mm). It holds 4.096 US gallons of water per foot.

What is the metric equivalent of NPS 10?

DN 250. DN is a dimensionless designator, not a measurement — DN 250 pipe does not measure 250 mm anywhere. Its actual outside diameter is 273.1 mm.